This chamber has a narrower bath and smaller volume than the RC-27. It also has embedded electrodes to support studies using field stimulation.
- Designed for field stimulation studies
- Rectangular, open-bath chamber
- Narrow bath
- Accommodates tissue or brain slice specimens
- Applications include patch clamp, and physiological measurements on cultured cells
Modeled on the RC-21 Series chambers, RC-21BRFS imaging chamber is designed for field stimulation studies.
- Designed for studies involving cardiac myocytes
- Field stimulation chamber
- Closed bath design
- Small volume with slotted bath
- Ideal for fluorescent, calcium and time-lapse imaging studies
The RC-29 is designed for slice studies requiring controlled atmospheric conditions.
- Designed for tissue slice studies
- Gas perfusion ports allow for controlled atmospheric conditions
- Provides for perfusate flow both above and below a tissue slice
- Provides good access for immersion optics and electrodes
- Can be used with either upright or inverted microscopes
- Large imaging area
- Slice anchors available
The dual slotted open bath construction of the excise patch chamber permits exchange of solution surrounding a membrane patch without contamination of the associated cell population.
- Designed for excised patch studies
- Open chamber design
- Dual slotted baths in two sizes
- Baths separated by a controllable dam
The RC-24 and RC-24E chambers allow for very fast solution exchange for a variety of applications. These recording chambers feature the smallest bath volumes of Warner’s open style chambers.
- Designed for physiological measurements of cell cultured coverslips
- Applications include patch clamp, imaging, and intracellular/extracellular recordings
- Diamond shaped bath provides laminar solution flow
- Both perfusion and aspiration ports on same side of chamber
- Very small bath volume facilitates very fast solution exchange
The RC-24N allows very fast solution exchange for a variety of applications. This recording chamber features the smallest bath volume of the open style chambers.
- Designed for physiological measurements of cell cultured coverslips
- Applications include patch clamp, intracellular/extracellular recordings, and imaging
- Diamond shaped bath provides laminar solution flow
- Very small bath volume facilitates very fast solution exchange
A large rectangular bath with a slice support and anchor increases slice viability during long term studies.
- Designed for tissue slice studies
- Permits solution flow both above and below a tissue slice
- Provides good access for immersion optics and electrodes.
- Can be used with either upright or inverted microscopes
- Slice anchors available
The RC-27 is a large bath chamber suitable for studies requiring smooth solution flow with a large viewing area.
- Accommodates large tissue sections or brain slices
- Large rectangular bath area accommodates insertion of coverslips up to 12 x 24 mm
- Large optical imaging area
- Can be used with either upright or inverted microscopes
- Slice anchors available
Primarily designed for studies of cell cultured coverslips.
- Applications include patch clamp, intracellular/extracellular recordings, and imaging
- Extra-low profile facilitates electrode access
- Diamond shaped bath provides laminar solution flow
- Broad optical imaging area
- Can be used with either upright or inverted microscopes
- Rectangular, open-bath chamber
- Narrow bath
- Accommodates tissue or brain slice specimens
- Applications include patch clamp, and physiological measurements on cultured cells and tissue preparations
- Slice anchors available with three thread spacing sizes
An open bath, polycarbonate recording chamber that uses 25 mm round coverslips and incorporates Warner’s diamond bath fluidics.
- Designed for physiological measurements on cell cultured coverslips
- Identical to the RC-21BRW except for a diamond shaped bath
- Uses A 25 mm round coverslip as the chamber floor
- Diamond shaped bath provides laminar solution flow
- Quiet operation
- Wicked solution removal from bath
- Can be used with upright or inverted microscopes
The RC-26Z, based on the the popular RC-26, is specifically designed to accommodate studies with xenopus oocytes.
- Designed for TEV oocyte recording
- Diamond shaped bath provides laminar solution flow
- Large optical imaging area
- Can be used with either upright or inverted microscopes
- Tissue slice anchors available
The RC-22 and RC-22C are small volume, open bath recording chambers designed for tissue and brain slice studies.
- Designed for tissue slice samples or cell cultured coverslips
- Applications include patch clamp, intracellular / extracellular recordings, and imaging
- Diamond shaped bath provides laminar solution flow
- Small bath volume facilitates rapid solution exchange
- Tissue slice anchor included
Open diamond bath recording chambers designed for round coverslips.
- Designed for physiological measurements of cell cultured coverslips
- Applications include patch clamp, intracellular/extracellular recordings, and imaging
- Uses 12 and 15 mm diameter round coverslips as the chamber floor
- Diamond shaped bath provides laminar solution flow
- Small bath volume facilitates fast solution exchange
This recording chamber features a round, wide aperture, open bath for maximum imaging area.
- Designed for physiological measurements on cell cultured coverslips
- Uses a 25 mm diameter round coverslip as the chamber floor
- Quiet operation
- Broad imaging area
- Wicked solution removal from bath
- Can be used with upright or inverted microscopes
The PFC-1 ProFlow chamber is based on the designs of Dr. Melissa Knothe Tate, currently of the Case Western Reserve University.
- Computer designed gaskets optimized for well-defined, well-controlled shear-flow
- Based on technology developed at Case Western Reserve University
- Single- and dual-flow capable chamber
- Made from polycarbonate for easy cleanup
The classic RC-26G chamber in a disposable, silicone format.
- Eliminates the need for a grease seal
- Incorporates Warner’s diamond fluidics
- Low cost for disposable applications
Polycarbonate chambers featuring fast perfusate exchange and linear solution flow.
- Closed bath chamber design
- Our smallest volume, closed bath chambers
- Ideal for fluorescent, calcium, and time-lapse imaging studies
- Eliminates vibration associated with solution exchange
- Incorporates Warner’s diamond fluidics
- Multiplexed solution delivery is possible without the potential of solution switching artifacts
Large volume open diamond bath recording chamber that can accommodate large specimens such as slice preparations.
- Designed for patch clamp studies
- Can be used with tissue slice samples or cell cultured coverslips
- Applications include patch clamp, intracellular / extracellular recordings, and imaging
- Diamond shaped bath provides laminar solution flow
- Large imaging area
- Can be used with upright or inverted microscopes
- Tissue slice anchors available
The RC-27D and RC-27LD are designed for applications requiring ultra quiet solution delivery.
- Designed for tissue slice studies
- RC-27LD includes slice support
- Eliminates vibration associated with solution delivery
- Alows multiplexed solution exchange without switching artifacts
Polycarbonate chambers providing a large viewing area and good access for microscope objectives.
- Closed bath chamber design
- Diamond fluidics
- Ideal for fluorescent, calcium, and time-lapse imaging studies
- Uses 22 mm square or 25 mm round coverslips
- Large optical imaging area