Differential Amplifier (DP-301)

The DP-301 is a single channel AC/DC differential pre-amplifier highly suited for EEG, EKG and extracellular recording.

  • High input impedance
  • High common mode rejection
  • Low noise with high gain
  • High tolerance to DC offsets
  • Bandwidth filtering available
Extracellular Differential Amplifier
Differential Amplifier with Active Headstage (DP-311)

The DP-311 AC/DC Differential Amplifier is highly suited for EEG, EKG and extracellular recording using glass or metal microelectrodes.

  • Excellent common mode rejection: 120 dB at 60 Hz
  • Small active headstage which can be mounted in micromanipulators
  • Suitable for use with high impedance glass or metal microelectrodes
Differential Amplifier with Active Headstage (DP-311)
Dual Channel Differential Electrometer (HiZ-223)

The HiZ-223 is a very high input impedance, dual channel electrometer designed for measurements with high resistance ion-selective microelectrodes.

  • 1015Ω Input Resistance
  • Designed for measurements with ion-selective microelectrodes
  • Probe Test Port
  • Standby mode protects input amplifiers
  • Driven Guard Shield reduces stray capacity and noise
Dual Channel Differential Electrometer (HiZ-223)
Intracellular Electrometer (IE-210)

A high impedance electrometer designed specifically for intracellular studies. The instrument consists of two sections; the probe headstage and the controller which contains the signal conditioning, monitoring and power circuitry.

  • High impedance microelectrode amplifier for intracellular studies
  • Simultaneous current injection stimulation and recording
  • Bridge Balance Output gains of x10, x20, and x50
  • Capacity Compensation for up to 50 pF
Intracellular Electrometer (IE-210)
Intracellular Electrometer (IE-251A)

The IE-251A is a moderately priced intracellular electrometer complete with current passing capability and incorporating the same basic design as the more costly IE-210.

  • Fixed gains of x1 and x10
  • Capacity Compensation neutralizes input capacitance for up to 50 pF
  • Junction potentials of up to ±200 mV are nulled with the DC Position control
  • Electrode Test provides convenient electrode resistance check
  • Push button operated Buzz produces oscillations at pipette tip to facilitate cell impalement
  • Convenient Probe Test port permits fast check of amplifier performance
Intracellular Electrometer (IE-251A)
Low-pass Bessel Filter (LPF-8)

A signal conditioner combining an 8-pole low pass Bessel filter with a DC amplifier.

  • Provides greater frequency control for Bilayer and Oocyte Clamps
  • High quality 8-pole Bessel filter
  • 8-Pole low pass Bessel filter with cutoff frequencies from 0.1 Hz to 20 kHz
  • Differential amplifier gains to x200
  • Frequency selection with single control
  • Input offset adjustment
  • Digital frequency readout
  • Rack mountable
Low-pass Bessel Filter (LPF-8)
Low-pass Bessel Filters (LPF-100B / LPF-202A)

These DC amplifier and signal conditioners are used to filter noise and boost signals to levels compatible with computers, chart recorders and tape recorders.

  • Single Channel LPF-100B
  • Dual Channel LPF-202A
  • Useful with Epithelial and Oocyte Clamps
Low-pass Bessel Filters (LPF-100B LPF-202A)
Patch Clamp Amplifier (PC-501A)

A workhorse patch clamp amplifier equally at home in research and teaching labs.

  • Independent V-hold and I-hold circuitry
  • Three current clamp response speeds increase stability of large membrane clamps
  • 4-pole low-pass Bessel filter
  • Internally generated test signals
  • Variable duration zap circuit
Patch Clamp Amplifier (PC-501A)
Patch Clamp Amplifier (PC-505B)

The lowest noise, switchable, resistive-feedback patch clamp amplifier currently available.

  • Lowest noise! Approaches theoretical limit
  • Calibrated cap comp and series R circuitry
  • % compensation circuitry
  • Independent V hold and I hold controls
  • Zap safety switch
  • LED meter
Patch Clamp Amplifier (PC-505B)
Differential Amplifier (DP-304A)

The DP-304A is a four channel AC/DC differential amplifier highly suited for EEG, EKG and extracellular recording.

  • High input impedance
  • High common mode rejection: 120 dB at 60 Hz
  • Low noise with high gain
  • High tolerance to DC baselines
Differential Amplifier (DP-304A)
Heka Patch Clamp Amplifiers (EPC 10 USB)

The EPC 10 USB patch clamp amplifier, combined with a computer and PATCHMASTER software is a fully equipped recording setup.

  • Computer controlled via PatchMaster Software
  • Integrated data acquisition
  • Three headstage configurations available
  • Available in Single, Double, Triple, and Quadro versions
  • Expandable to as many as 64 recording channels
Heka Patch Clamp Amplifiers (EPC 10 USB)